4-3-2 Quantity Preset
The scale can store a Hi Limit quantity value. The scale will make a warning beep
and the unit weight window will display a blinking . if the quantity is
over the Hi limit alarm value set.
Hi Limit Value for Quantity Preset
Œ Press
QTY PST
key whether the scale has object on the weigh pan or not.
0
3
Stable
3
Latest Preset Value
Enter a desired Hi Limit value. Use
CE
key to correct the value entered.
0
3
Stable
3
Hi Limit Value Entered
Ž Press
SMPL
key. Use
CE
key to correct the value entered.
0
3
Stable
3
Press
QTY PST
key, the scale will return to counting mode.